System crash dump analysis report
=================================
Symptom
System hang, INIT dump be taken for cause analysis.
Root Cause
----------
CISS: RAID SA controller on hardware path 0/4/1/0/4/0 has detected ECC
errors in the SIMM modules. Controller be taken offline.
PV /dev/dsk/c4t0d0s2 is the PV of /dev/vg00, which leads system
block on IOs and then system hang.
Action Plan
-----------
Open hardware repair case for ciss PCI-X SmartArray 6402 RAID Controller
at address 0/4/1/0/4/0 is recommended.
Detail Analysis
===============
=======================
= General Information =
=======================
Dump time Thu Mar 4 11:05:16 2010 UTC-8
System has been up 37 days, 2 hours, 39 minutes.
Node Name : localhost
Model : server rx2620
BIOS revision : 04.29
HP-UX version : B.11.23
Kernel whatstring : @(#) $Revision: vmunix:
B11.23_LR FLAVOR=perf Fri Aug 29 22:35:38 PDT 2003 $
Number of CPU's : 4
Disabled CPU's : 0
CPU type : IA64 (1.4 Ghz)
CPU Architecture : IA-64 0
Load average : 0.50 0.50 0.51
================
= Crash Events =
================
Crash event 0 was a INIT !
This seems to be a user initiated INIT !
Stack Trace for crash event 0
=============================
============== EVENT ============================
= Event #0 is CT_INIT on CPU #1;
= p crash_event_t 0xe000000100007000
= p rpb_t 0xe0000001013bab80
============== EVENT ============================
RR0=0x00ffff31 RR1=0x00ffff31 RR2=0x00ffff31 RR3=0x00ffff31
RR4=0x33bfc831 RR5=0x00ffff31 RR6=0x00ffff31 RR7=0x00dead31
BSP SP IP
0xe0000001013c4000 0xe0000001013d7b90 0xe0000000006ce8c0 idle+0x560
0xe0000001013c4000 0xe0000001013d7bf0 0xe000000000e3d020 os_rendez_ihandler
------------------------------------------------------
0/4/1/0/4/0 ciss PCI-X SmartArray 6402 RAID Controller
CISS: RAID SA controller on hardware path 0/4/1/0/4/0 has detected ECC
errors in the SIMM modules. Controller will be taken offline.
CISS: RAID SA driver on hardware path 0/4/1/0/4/0 is being taken offline,
reason code 0x2
Reason codes:
0x01 = Initialization failed.
0x02 = Firmware crash.
0x05 = Download timeout.
0x06 = Firmware initialization timeout.
SCSI: Read error -- dev: b 31 0x040000, errno: 126, resid: 1024,
blkno: 8, sectno: 1024050, offset: 8192, bcount: 1024.
LVM: VG 64 0x000000: Lost quorum.
This may block configuration changes and I/Os. In order to reestablish
quorum at least 1 of the following PVs (represented by current link)
must become available:
<31 0x040002>
LVM: VG 64 0x000000: PVLink 31 0x040002 Failed! The PV is not accessible.
Hardware Path: 0/4/1/0/4/0 ( ciss )
Hardware Path: 0/4/1/0/4/0.0.0 ( sdisk )
--- Volume groups ---
VG Name /dev/vg00
VG Write Access read/write
VG Status available
Max LV 255
Cur LV 9
Open LV 9
Max PV 16
Cur PV 1
Act PV 1
Max PE per PV 4328
VGDA 2
PE Size (Mbytes) 16
Total PE 4318
Alloc PE 4318
Free PE 0
Total Spare PVs 0
Total Spare PVs in use 0
--- Physical volumes ---
PV Name /dev/dsk/c4t0d0s2
PV Status unavailable
Total PE 4318
Free PE 0
Autoswitch On
|